EasyManua.ls Logo

Vega VEGAMET 861 - Switch-on phase

Vega VEGAMET 861
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
5 Connecting to power supply
VEGAMET 861 • 4 … 20 mA/HART
58866-EN-200401
Detail sensor connection 1
+-+-
1 23 1 23
3
1
6
5
4
2
Fig. 7: Sensor input 1 for two-wire/four-wire sensor (active/passive)
1 Active input with sensor supply for two-wire sensor
2 Passive input without sensor supply for four-wire sensor
2)
3 Two-wire sensor
4 Four-wire sensor
5 Voltage supply for four-wire sensor
6 2 mm sockets for connection of a VEGACONNECT/HART handheld
Detail, digital inputs VEGAMET 861
+- +-
1 2
+- +-
3 4
21 22 23 24 25 26
Fig. 8: Connection of the digital inputs
1 Digital input 1 (active)
2 Digital input 1 (passive)
3 Digital input 2 (active)
4 Digital input 2 (passive)
Connection assignment digital inputs
21 22 23
+
-
1
3
21 22 23
+
-
2
4
3
Fig. 9: Connection assignment of the digital inputs (active/passive)
1 Activeinputforoatingswitchingcontact
2 Passive input for switching contact and external voltage supply
3 Switching contact
4 External voltage source
5.6 Switch-on phase
Afterswitchingon,thedevicerstcarriesoutashortself-check.
Internal check of the electronics
2)
Passive input not available for Ex version

Table of Contents

Other manuals for Vega VEGAMET 861

Related product manuals