14 Supplement
VEGAPULS C 23 • Modbus and Levelmaster protocol
58349-EN-200806
Set Receive to Transmit Delay
Parameter Length Code/Data
Request: Set Receive to Transmit
Delay
7 characters ASCII UuuRmmm
mmm = milliseconds (50 up to 250),
default = 127 ms
Response: Set Receive to Transmit
Delay
6 characters ASCII UuuROK
Report Number of Floats
Parameter Length Code/Data
Request: Set Receive to Transmit
Delay
4 characters ASCII UuuF
Response: Set Receive to Transmit
Delay
5 characters ASCII UuuFn
n = number of measurement values
(0, 1 or 2)
Report Receive to Transmit Delay
Parameter Length Code/Data
Request: Report Receive to Transmit
Delay
4 characters ASCII UuuR
Response: Report Receive to Transmit
Delay
7 characters ASCII UuuRmmm
mmm = milliseconds (50 up to
250), default = 127 ms
Error codes
Error Code Name
EE-Error Error While Storing Data in EEPROM
FR-Error Erorr in Frame (too short, too long, wrong data)
LV-Error Value out of limits