SI23 Solar Pump VFD Manual
33
F10.50(0x0A32)
Failure
self-recovery
V/F SVC FVC
Set the number of fault self-recovery that is
allowed to be performed.
Note: A value of 0 indicates that the fault
self-recovery function is turned off; otherwise it
indicates that the function is enabled.
0
(010)
F10.51(0x0A33)
Failure
self-recovery
interval
V/F SVC FVC
Set the waiting time before the VFD resets to
the time before each reset.
1.0s
(0.0s100.0s)
F10.52(0x0A34)
Numbers of
failures
recovered
V/F SVC FVC
Indicates the number of self-recovery faults that
have been performed. This parameter is a
read-only parameter.
0
Operation Parameters
Parameter
(address)
Function
Description
Range of settings and definition
Factory default
(setting range)
Notes
F11.00(0x0B00)
Key lock
selection
V/F SVC FVC
0: Not locked.
1: Keyboard function parameter modification
lock.
2: Function parameters and non-start stop
button lock.
3: Function parameters and button full lock.
0
(03)
F11.01(0x0B01)
Key lock
password
V/F SVC
0
(065535)
F11.11(0x0B0B)
Parameter 1
showed up on
first line of the
keyboard
V/F SVC FVC
LED "0" and "00" digit: Setting yy setting in
monitoring parameter number Cxx.yy
0063.
LED "000" and "0000" digit: Monitoring
parameter number Cxx.yy xx setting
0007.
0000
(00000763)
F11.12(0x0B0C)
Parameter 2
showed up on
first line of the
keyboard
V/F SVC FVC
LED "0" and "00" digit: Setting yy setting in
monitoring parameter number Cxx.yy
0063.
LED "000" and "0000" digit: Monitoring
parameter number Cxx.yy xx setting
0007.
0001
(00000763)
F11.13(0x0B0D)
Parameter 3
showed up on
first line of the
V/F SVC FVC
LED "0" and "00" digit: Setting yy setting in
monitoring parameter number Cxx.yy
0002
(00000763)