EasyManua.ls Logo

Veit SG67 - Steam Supply and Boiler Specs

Veit SG67
87 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Tab. 5: Steam supply
VEIT SG67
2.2 kW
VEIT SG67
4.4 kW
VEIT SG67-C
4.4 kW
VEIT SG67
6.6 kW
Connection 3/8'' 2 x 3/8" 2 x 3/8" 2 x 3/8"
Operating pressure 3.5 - 4.0 bar /
0.35 - 0.40 MPa
3.5 - 4.0 bar /
0.35 - 0.40 MPa
2.5 - 5.0 bar /
0.25 -0.50 MPa
3.5 - 4.0 bar /
0.35 -0.40 MPa
Saturated steam capacity 3 kg/h 6 kg/h 6 kg/h 9 kg/h
Steam consumers 1 iron 2 irons 2 irons 2 irons
Tab. 6: Boiler
VEIT SG67
2.2 kW
VEIT SG67
4.4 kW
VEIT SG67-C
4.4 kW
VEIT SG67
6.6 kW
Connected load without irons 2.2 kW 4.4 kW 4.4 kW 6.6 kW
Water capacity until reaching the
minimum water level
3.0 l 3.0 l 3.0 l 3.0 l
Total boiler volume 6.5 l 6.5 l 6.5 l 6.5 l
Pre-set operating pressure 3.5 - 4.0 bar /
0.35 -0.4 MPa
3.5 - 4.0 bar /
0.35 -0.4 MPa
2.5 - 5.0 bar /
0.25 -0.5 MPa
3.5 - 4.0 bar /
0.35 -0.4 MPa
Maximum operating pressure 7 bar / 0.7 MPa 7 bar / 0.7 MPa 7 bar / 0.7 MPa 7 bar / 0.7 MPa
Saturated steam capacity 2.8 kg/h 5.7 kg/h 5.7 kg/h 8.6 kg/h
Tab. 7: General Data
Protection category IPXXC
Intended use
Technical data
30.09.2022
Steam generator VEIT SG67
11