C
G
R
Y
1
W2
W
1
Y2
O
B
POWER
R
COMPRESSOR
Y
FAN
G
COMMON
C
2nd STAGE
HEATING
W2
Sample Wiring Diagrams
Heat Pump
6 Wire, 1 Stage Cooling, 2 Stage Heat-Heat Pump* with O or b reversing valve**.
Residential Heat Pumps, split systems & package units, with auxiliary heat.
* This option must be selected ON during advanced setup
(see page 11, step #4 of Owner’s Manual).
** This option must be selected O or b during advanced setup
(see page 11, step #5 of Owner’s Manual).
O/B
REVERSING VALVE**