STEP #4
TEST OPERATION
Press the MODE button repeatedly until
the HEAT icon appears on the display.
Press the UP or DOWN buttons until the set
temperature is 10 degrees above room
temperature. The HVAC unit should
energize in the heating mode.
Turn the power on to the Heating/Air
Conditioning system.
Press the UP button until the setpoint is
equal to the room temperature. Press the
FAN button to Fan On. The fan should turn
on and run continuously.
Press the MODE button repeatedly until
the COOL icon appears on the display.
Press the UP or DOWN buttons until the set
temperature is 10 degrees below room
temperature. The HVAC unit should
energize in the cooling mode.
NOTE: Most equipment has a time delay
of 5 minutes between cool cycles. This
feature is defeatable on the thermostat
(see page 12, step #9 of Owner's Manual).