Omni 3200 Reference Manual
118 Descriptions of Diagnostic and Debugging Commands
Descriptions of Diagnostic and Debugging
Commands
The commands for remote diagnostics and debugging are listed in
alphabetical order below. These commands must be executed at the
remote diagnostics or debugging computer and cannot be initiated
from the terminal.
Note: Several commands can only be used for debugging. These
commands are noted in the respective command heading as for
(Debugger Only).
B — Get Static Registers (Debugger Only)
The B command asks the terminal to send the contents of the PB, EB,
HB, and ML static registers. The terminal sends the contents of each
register back to the diagnostic computer. The requested registers are
each two bytes in binary, with the least significant byte first.
Command Packet Received by Terminal:
<FFh> <55h> <count> B <CRC1> <CRC2>
Response Packet Sent by Terminal:
<FFh> <55h> <count> B <PB> <EB> <HB> <ML> <CRC1>
<CRC2>
63 * Transmit timeouts on LAN port
64 * Runt packages received on LAN
65–68 * Reserved for future use
Table 28 Diagnostic Counters
Counter Description of Event
O3200 RM Book.book Page 118 Thursday, April 29, 1999 3:48 PM