Page #38 background image
Table 2-4
Control panel LED conditions and statuses (continued)
StatusAssociated
LEDs/Alarms
Logical
Fault
(Amber)
Module
Fault
(Amber)
System
Power
(Green or
Amber)
Any Power Cooling Module
Fault, Fan Fault, or an over or
under temperature issue
Power Cooling
Module Fault
LEDs
Fan Fault LEDs
N/AOn (Amber)On (Green)
Any I/O module faultI/O module
LEDs
N/AOn (Amber)On (Green)
Enclosure Logical FaultNoneN/AOn (Amber)On (Green)
Unknown I/O module type
installed
(Invalid or Mixed)
Module Fault
LED on an I/O
module
N/AFlashingOn (Green)
Unknown Power Cooling
Module installed.
(Invalid or Mixed)
Power Cooling
Module Fault
LEDs
Fan Fault LEDs
N/AFlashingOn (Green)
Drive failure has occurred
causing loss of availability or
redundancy
Array in a failed
or degraded
state
OnN/AOn (Green)
Array operating background
function
Arrays in an
impacted state
FlashingN/AOn (Green)
Enclosure ID setting different
from "start of day" setting
SES state S1N/AFlashingOn
N/A - Not Applicable
For more information, see the NetBackup Appliance Hardware Installation Guide -
Release 3.0 - NetBackup 5240.
Veritas 2U12 49TB Storage Shelf rear components
This section describes the rear panel features of the Veritas 2U12 49TB Storage
Shelf.
38About the Veritas 2U12 49TB Storage Shelf
Veritas 2U12 49TB Storage Shelf rear components

Table of Contents

Other manuals for VERITAS NetBackup 5240

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the VERITAS NetBackup 5240 and is the answer not in the manual?

VERITAS NetBackup 5240 Specifications

General IconGeneral
Language version-
License typeCorporate
License quantity- license(s)
License term in years5 year(s)

Related product manuals