VX-150 OPERATING MANUAL 33
Set Mode Details
Set Item 1
[
ALPHA
]
Function: Store Alpha-Numeric “Tags” for the Memory channels.
See page 19 for details.
Set Item 2
[
ARS
]
Function: Enable/disable the Automatic Repeater Shift function.
Available Values: ON/OFF
Default: ON
Set Item 3
[
RPT
]
Function: Set the Repeater Shift Direction
Available Values: -RPT/SIMP/+RPT
Default: SIMP
Set Item 4
[
SHIFT
]
Function: Set the magnitude of the Repeater Shift.
Available Values: 0.00 ~ 99.9 MHz
Default: Depends on the transceiver version, as well as the setting of Menu #2 (ARS).
Set Item 5
[
V-SPLIT
]
Function: Enable/disable “VFO Split” Operation
Available Values: ON/OFF
Default: OFF
Set Item 6
[
STEP
]
Function: Setting of the synthesizer steps.
Available Values: 5/10/12.5/15/20/25/50 kHz
Default: Depends on the transceiver version.
Set Item 7
[
RESUME
]
Function: Select the Scan Resume mode.
Available Values: 5 SEC/BUSY/HOLD
Default: 5 SEC
Set Mode
Item #
35
36
37
38
Menu Item
DT DLY
ANI
BATT
SKIP
Function
Select the DTMF Autodialer delay time
Program and activate the ANI Identifier
Indication of the Supply Voltage
Enable/Disable skipping of a memory during
scanning
Available Values
450 ms/750 ms
–
–
ON/OFF
Default
450 ms
–
–
OFF
ÛDepends on the transceiver version