VX-150 OPERATING MANUAL34
Set Mode
Set Item 8
[
SCN LMP
]
Function: Enable/disable the Scan lamp while paused.
Available Values: ON/OFF
Default: ON
Set Item 9
[
RX SAVE
]
Function: Select the Receive-mode Battery Saver interval (“Sleep” ratio).
Available Values: OFF/200ms(1:1)/300ms(1:1.5)/500ms(1:2.5)/1s(1:5)/2s(1:10)
Default: 200ms(1:1)
Set Item 10
[
TX SAVE
]
Function: Enable/disable the Transmit Battery Saver.
Available Values: ON/OFF
Default: OFF
Set Item 11
[
APO
]
Function: Set the Automatic Power-Off time.
Available Values: OFF/30 min/1 hour/3 hour/5 hour/8 hour
Default: OFF
Set Item 12
[
TRX LED
]
Function: Enable/ disable the BUSY/TX LED while the Squelch is open or during trans-
mission.
Available Values: ON/OFF
Default: ON (Lamp active)
Set Item 13
[
ARTS
]
Function: Activate the ARTS feature.
See page 27 for details.
Set Item 14
[
ARTS BP
]
Function: Select the Beep option during ARTS operation.
Available Values: OFF/INRANGE/ALWAYS
Default: INRANGE
Set Item 15
[
AR ITVL
]
Function: Select the Polling Interval during ARTS operation.
Available Values: 15 SEC/25 SEC
Default: 15 SEC
Set Item 16
[
KEY BP
]
Function: Enable/disable the Keypad beeper.
Available Values: ON/OFF
Default: ON