15VX-1700 Series (EXP Version) Service Manual
F
INAL SECTION IDLING CURRENT ALIGNMENT
Connect the 50 Ohm Dummy Load to the ANT
jack.
Remove the solder jumper which is connected
between TP2020 and TP2021 on the PA Unit, then
connect the “+” lead of the DC Ammeter to
TP2020 and the “–” lead to TP2021.
Set VR2003 on the PA Unit fully counter-clock-
wise.
Tune the radio to 7.500 MHz, USB mode.
Key the transmitter (connect pin 3 of the MIC jack
to GND) with no microphone input, and adjust
VR2003 for 300 mA (±30 mA) on the DC Amme-
ter.
Disconnect the DC Ammeter, and re-connect the
solder jumper between TP2020 and TP2021.
CM COUPLER BALANCE
Connect the 50 Ohm Dummy Load and Inline
Wattmeter to the ANT jack, and connect the CW
keyer to the KEY jack.
Connect the DC voltmeter to TP2018 (“+” lead,
“–” lead: GND) on the PA Unit.
Tune the radio to 29.000 MHz, A1A mode.
Key the transmitter (close the CW key).
Now adjust TC2001 on the PA Unit for minimum
indication on the DC voltmeter.
Alignment

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vertex Standard VX-1700 Series and is the answer not in the manual?

Vertex Standard VX-1700 Series Specifications

General IconGeneral
BrandVertex Standard
ModelVX-1700 Series
CategoryRadio
LanguageEnglish

Related product manuals