FCC ID: K6610354640
IC ID: 511B-10354640
Alignment
2
/
10
Vertex Standard Co., Ltd.
Required Test Equipment
RF Signal Generator with calibrated output level at 500 MHz
Deviation Meter (linear detector)
In-line Wattmeter with 5 % accuracy at 500 MHz
50 RF Dummy Load with power rating 100 W at 500 MHz
4 /12 W AF Dummy Load (Attention : Audio output is BTL output)
Regulated DC Power Supply (standard 13.6 V DC, 15 A)
Frequency Counter with 0.2 ppm accuracy at 500 MHz
Audio Signal Generator (available to output 30 Hz to 5 kHz)
AC Voltmeter
DC Voltmeter
UHF Sampling Coupler
IBM PC / compatible Computer with Microsoft Windows95 or later operating system
Vertex Standard VPL-1 Connection Cable & CE59 Programming software.
Alignment Preparation & Precautions
A 50 RF Dummy Load and in-line wattmeter must be connected to the main antenna
jack in all procedures that call for transmission, except where specified otherwise. Correct
alignment is not possible with an antenna.
After completing one step, read the following step to determine whether the same test
equipment will be required. If not, remove the test equipment (except dummy load and
wattmeter, in connected) before proceeding.
Correct alignment requires that the ambient temperature be the same as that of the
transceiver and test equipment, and that this temperature be held constant between 20 and
30°C (68 - 86 °F). When the transceiver is brought into the shop from hot or cold air, it should
be allowed time to come to room temperature before alignment.
Whenever possible, alignments should be made with oscillator shields and circuit boards
firmly affixed in place.
Also, the test equipment must be thoroughly warmed up before beginning.
Note: Signal levels in dB referred to in the alignment procedure are based on
0dBµ EMF = 1µV.
Setup the test equipment as shown for transceiver alignment, apply 13.6V DC power to
the transceiver. Refer to the drawings above for Alignment Points.