Specifications26
Table 6-1 UPS Specifications (continued)
CAPACITY 1000 VA/ 900 W 1500 VA/ 1350 W 2000 VA/ 1800 W 3000 VA/ 2700 W
GXTRT- 1000IRT2UXL 1500IRT2UXL 2000IRT2UXL 3000IRT2UXL
BATTERY
Battery Type Valve-regulated, non-spillable, lead acid
Quantity x
Voltage x Rating
2 x 12V x 9Ah 3 x 12V x 9Ah 4 x 12V x 9Ah 6 x 12V x 9Ah
Recharge Time 4 hours recover to 90% capacity (Typical)
Charging
Current
1.0 A (max.)
Charging
Voltage
27. 2 VDC ± 1% 40.9 VDC ± 1% 54.4 VDC ± 1% 81.7 VDC ± 1%
PHYSICAL
Unit Dimensions
D X W X H (mm)
312 x 438 x 88 462 x 438 x 88 632 x 438 x 88
Unit Weight
(kgs)
11 14.5 18.2 27.6
Shipping
Dimensions D X
W X H (mm)
600 x 500 x 240 700 x 565 x 240 760 x 600 x 240
Shipping Weight
(kgs)
13.1 16.8 20.7 31.2
MANAGEMENT
Smart RS-232 or
USB
Supports Windows® 2003/XP/Vista/2008/7/8/2012/10/2016/2019, Linux, and MAC
Optional SNMP Power management from SNMP manager and web browser
AGENCY
Safety CE Mark; IEC/EN 62040-1: 2014
EMI IEC/EN 62040-2:2006+AC:2006 Class A
Surge Immunity EN 61000-4-5: 2005 Class 2 L-N, Class 3 L-G
Transportation ISTA 2A
ENVIRONMENTAL REQUIREMENTS
Operating
Temperature, °C
0 to 50*
Storage
Temperature, °C
-20 to 50
Operating
Relative
Humidity
20% to 90%, non-condensing
Storage Relative
Humidity
10% to 90%, non-condensing
Operating
Elevation
2000 m without derating. Between 2000 and 3000 m, derate 1% for every 100m.
Operation above 3000 m is not supported.
Noise Level 55 dBA Max @ 1 Meter
*To extend battery life, it is recommended to use the UPS in the range of 15 - 25 °C.
The threshold of low line transfer and low line comeback is increased when Ambient Temp. is 35 - 50 °C.
70% derating of output when Ambient Temp. is 40 - 50 °C.
The overload capacity is decreased when Ambient Temp. is 40 - 50 °C.
Transfer to bypass mode and show temp. alarm when Ambient Temp. > 50 °C and transfer back to online mode when Ambient Temp. < 40 °C.

Other manuals for Vertiv LIEBERT GXT RT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vertiv LIEBERT GXT RT Series and is the answer not in the manual?

Vertiv LIEBERT GXT RT Series Specifications

General IconGeneral
BrandVertiv
ModelLIEBERT GXT RT Series
CategoryUPS
LanguageEnglish

Related product manuals