Liebert® Mini-Mate2
2 & 3 Ton (7 & 10.5kW)Capacity, Air, Water, Glycol,
ChilledWater; 50&60Hz
Technical Data Manual
Question and Answer IconNeed help?

Do you have a question about the Vertiv Liebert Mini-Mate2 MMD24E and is the answer not in the manual?

Vertiv Liebert Mini-Mate2 MMD24E Specifications

General IconGeneral
BrandVertiv
ModelLiebert Mini-Mate2 MMD24E
CategoryAir Conditioner
LanguageEnglish

Summary

Introduction

1.1 Designed to Match Computer and Electronic Equipment Needs—From Installation to Operation

Explains how the system meets electronic equipment cooling needs from installation to operation.

Standard Features—2 & 3 Ton Systems

2.1 Evaporator Section - Split Systems

Details the construction and features of the split system evaporator section.

2.2 Condensing Unit Section—Split Systems

Covers the features of split system condensing units, including types like indoor/outdoor.

2.3 Chilled Water Units

Describes the features and construction of the chilled water system units.

2.4 System Controls

Explains the microprocessor control system, wall-mounted interface, and alarm functions.

Optional Factory-Installed Features—Evaporator/Chilled Water Units

3.1 Reheat

Describes electric and hot water reheat options for temperature control.

3.2 Humidifier

Details canister humidifiers and remote humidifier contact options.

3.3 Sensors

Explains smoke and high-temperature sensors for safety and unit shutdown.

3.4 Switches and Motors

Covers filter clog switches and blower options.

3.5 Free-Cooling

Describes the free-cooling option for energy efficiency using ambient air.

3.6 Optional Configurations—Prop Fan Condensing Units

Lists optional configurations for outdoor prop fan condensing units.

3.7 Optional Configurations-Water/Glycol Condensing Units

Lists optional piping configurations for indoor water/glycol condensing units.

3.8 Optional Configurations—Chilled Water Units

Lists optional valve options for chilled water units.

Ship-Loose Accessories—Field-Installed

4.1 Remote Monitoring, Autochangeover, and Leak Detection Equipment

Covers accessories for system monitoring, control, and leak detection.

Flexible Configurations

Air-Cooled Systems—Capacities and Dimensions

Water/Glycol Systems—Capacities and Dimensions

Chilled Water Systems—Capacities and Dimensions

Electrical Data

Refrigerant Piping

Glycol Loop Piping

Model Number Nomenclature—All Systems

APPENDICES

Appendix A: Guide Specifications for Liebert Mini-Mate2 - 2- and 3-Ton

Contains detailed guide specifications for the 2- and 3-ton Liebert Mini-Mate2 capacity.

GUIDE SPECIFICATIONS

1.0 General

Outlines general requirements, design needs, submittals, quality assurance, and alternatives.

PRODUCT

2.1 Standard Features/All Systems

Details standard features applicable to all Liebert Mini-Mate2 systems.

2.2 System Components

Covers components for DX evaporators, chilled water systems, and various condensing units.

2.3 Factory-Installed Options

Lists optional features like reheat, humidifier, sensors, and free-cooling.

2.4 Ship-Loose Accessories

Describes field-installable accessories such as sensors, filters, line sets, and monitoring systems.

Execution

3.1 Installation of Air Conditioning Unit

Details general installation procedures, including wiring and piping.

3.2 Field Quality Control

Outlines startup procedures and compliance testing for the unit.