05
Step 2: Please open the water injection po and add pure water to the cooling system.
Please obsee the water level during the water injection process.
Step 3: Please take out the smoke pipe, one end of the smoke pipe is connected to the
exhaust po of the equipment, and the other end is connected to the outdoor.
Note: Please x the connection with a pipe clamp to prevent it from falling o.
★ The above picture is the smoke purication lter, please clean or
replace it in time according to the actual working conditions.
Check the water level in the water tank.
The rst staup of the new chiIler empties the air in the water pipe, Ieading
a slight water leve I decIine, but in order to keep the water IeveI in the
green area, it' s aIIowed to add adequate water aga i n. PIease obsee and
record the current water IeveI, and inspect it again after the chiller running
for a period of time, i f the water IeveI drops obviousIyt. PIease re-inspest
the water pipeline leakage.
FULL
NORMAL
ALARM