05
Step 2: Please open the water injection po and add pure water to the cooling system.
Please obsee the water level during the water injection process.
Step 3: Please take out the smoke pipe, one end of the smoke pipe is connected to the
exhaust po of the equipment, and the other end is connected to the outdoor.
Note: Please x the connection with a pipe clamp to prevent it from falling o.
★ The above picture is the smoke purication lter, please clean or
replace it in time according to the actual working conditions.
Check the water level in the water tank.
The rst staup of the new chiIler empties the air in the water pipe, Ieading
a slight water leve I decIine, but in order to keep the water IeveI in the
green area, it' s aIIowed to add adequate water aga i n. PIease obsee and
record the current water IeveI, and inspect it again after the chiller running
for a period of time, i f the water IeveI drops obviousIyt. PIease re-inspest
the water pipeline leakage.