13
Operation
The parallel function will not
synchronize the drives, they will just
move simultaneously. Depending on
the load of each drive, over time there
might show differences of the tilt
angles of the back and leg motors.
In this case use button to move all 1
drives completely up. After that the
motors should move parallel again.
4.5 Memory positions
Adjust the bed until you have reached
a comfortable position. Then proceed
as follows:
• Press button 3 times followed by w
one of the memory buttons , or 9 ß
q.
• The current position is assigned to
the corresponding memory button
and saved.
Stored positions can be recalled with
the memory buttons.
Proceed as follows:
• Press one of the buttons , or 9 ß q
and keep it pressed.
• The adjustment drives will move to
the saved positions and switch
off then.
Behavior of the memory positions with
activated parallel function
Memory positions are stored in the
radio remote control. If the parallel
function is on, a maximum of 6
positions is available (3 positions on
radio remote control 1 + 3 positions on
radio remote control 2).
If the parallel function is off, only 3
positions of the corresponding remote
control are available for each bed.
If you want an identical memory posi-
tion on both radio remote controls,
you must program it on both of them.
Stored memory positions will be over-
written if you save a new memory
position.