6000counts Pocket Clamp Multimeter
3Technical Specifications
3-1DC voltage (DCV)
Input impedance: 10MΩ ; Overload protection: 6V range is 550V DC or AC peak; the rest is 1000V DC or 750V AC peak.
The specific operations are as follows:
1. Insert the black test lead into the COM jack and the red test lead into the V/Ω /Hz jack.
2. Turn the range switch to the corresponding range, which is displayed as the automatic DC voltage measurement mode. The internal switch
will switch to the corresponding range according to the measured value of the input value.
3. The test pen is reliably contacted with the test point, and the screen displays the measured voltage value. When measuring the DC voltage display,
the red test pen is the voltage polarity of the connected point.
Note
1) Do not exceed the input voltage of DC1000V or AC750V. If it exceeds, there is danger of damage to the instrument circuit.
2) When measuring high voltage circuit, pay special attention to avoid electric shock.
3) After completing all measurement operations, disconnect the test leads from the circuit under test.
3-2AC voltage(ACV)
6000counts
Resolution
±(0.8%+3
0.001V
0.01V
0.1V
±(1.2%+10
1V
6000counts
Resolution
±(0.5%+3
0.001V
0.01V
0.1V
±(0.8%+10
1V
V