57
• PressENTER and the display will read:
• The central key in each unit
will begin to
flash on and off. Insert the blind filter (Fig 2 A06)
into the filter-holder, add half a dose of PULICAFF
and attach the filter-holder into the unit where you
intend to carry out the automatic cleaning cycle.
Carrying out a cleaning cycle in more than one unit
at a time is possible.
• Press the
key to start the unit automatic
cleaning cycle. The display will read:
where 1L indicates that the cleaning cycle has
been activated within the 1st unit. Once the cycle
of 15 deliveries of 5 seconds each, with a 10-
second pause between each delivery, has been
completed the selected unit
key will begin to
flash on and off again and the display will read.
•
Eliminate any residues of PULICAFF from the blind
filter and press
the rinsing cycle starting up key
of the unit or units where the cleaning cycle has been
effected. The letter R will remain on the display like the
key
. Once the rinsing cycle of the selected unit
or units has been completed, the display will read.
PROGRAMMING DOSES
• Pressthe key to access the programming; the
display will read:
• PressENTER and the display will read:
All the programmable keys will start to flash on and off.
• Press the coffee key you wish to program; the
display will read:
Followed by the dose amount already set by the
manufacturers.
• Varythedose,bypressingthebuttons.
• Bypressingthecoffeekeyyouwanttoprogram,
delivery will be started up (in the meantime all the
other keys will turn off).
• Selectthedoseofdeliveredcoffeeandthenpress
the coffee key you want to program again.
• Thedisplaywillshowthenewdoseamountwhich
can still be changed by means of the keys .
AUTO. CLEAN. CYCLE
SELECT
AUTO. CLEAN. CYCLE
1L
RINSE
MACHINE READY
PROGRAM. DOSES
PROGRAM. DOSES
SELECT
volume c.c:

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Victoria Arduino ADONIS 3 gruoups and is the answer not in the manual?

Victoria Arduino ADONIS 3 gruoups Specifications

General IconGeneral
BrandVictoria Arduino
ModelADONIS 3 gruoups
CategoryCoffee Maker
LanguageEnglish

Related product manuals