119
The mechanical setting consists in to adjust
the air tap on top of the machine to get a
proper foam quality.
It is a flat screw to open and close the air.
The machine arrives with a basic setting,
but if a maintenance has been done, the
starting point is to close completely the
screw clockwise and then open anti-clock-
wise about 2 complete turns.
HOW TO SET
DANGER
This operation is carried out with the
machine switched ON so as to perfectly
fine tune the air valve.
To set the Easycream, proceed as it follows.
Utilizing the Victoria Arduino E1 App, in
the programming of the MACHINE SET-
TING, enable Easycream and save.
97
96
98