4.6 HIGH-LIMIT THERMOSTATS
The high-limit thermostats are connect-
ed in series with the heating element and
opens the electrical circuit once the tem-
perature limit of 135°C in the infusion group
has been exceeded.
If the heating element does not turn ON,
check the continuity of the high-limit
thermostat.
If there is not continuity, rearm the
high-limit thermostat pushing into the
hole (A) by a small screwdriver.