User Manual for RS and RSA Refrigerators Victory
Rev. 07/24Victory12
Icons
Increase
Decrease
USING THE UNIT
Operation is simple, just keep it connected to the correct
power supply and the refrigerator will maintain the
internal temperature it has been set to. Keep the doors
closed as much as possible to avoid unnecessary run time.
The controller displays the current internal temperature.
Adjusting the set temperature lower will NOT cause the
system to lower the temperature faster. When on, the
refrigeration system is always operating at maximum.
The temperature was set at the factory at 38
º
F, but you
can adjust it to your own selected temperature. See page
15.
The Refrigerator will automatically defrost as needed,
there is no set time for defrost. Push and immediately
release the "melting" or defrost button for a manual
defrost.
The internal fan will be on when the compressor is on and
when the doors are closed.
The compressor and condenser fan motor will only be on
when the controller senses an increase in internal cabinet
temperature passed the set point.
Display
Changes begin with SET