1. If the range hood or lights do not operate after
installation:
Check if the range hood has been plugged in,
make sure that all power has been turned back
ON, fused not blown and all electrical wiring
are properly connected.
Swap out light assembly to working ones to
determine whether it is caused by defective
bulbs. See Replacing the light bulbs page.
2. The range hood vibrates when the blower is
on:
The range hood might not have been secured
properly on to the ceiling or wall.
3. The blower or fan seems weak: Duct is too small. Range hood WILL NOT
function e󰀩ciently with insu󰀩cient duct size.
For example: Connecting this hood to 4”, 5’ or
6” duct will reduce the suction and create extra
noise and vibrations. Check if duct is clogged
or if damper unit is not installed correctly or
opening properly. A tight mesh on a side wall
cap unit might also cause restriction to the air
ow.
4. The lights work but the blower is not spinning
at all, is stuck or is rattling.
The blower might be jammed or scraping the
bottom due to shipping damage. Please con-
tact us immediately.
5. The hood is not venting out properly: Make sure the distance between the stove top
and the bottom of the hood is within* 24” and
30” in distance. *Due to dierent ceiling height
congurations, recommended height may not
be applicable.
Reduce the number of elbows and length of
duct work. Check if all joints are properly con-
nected, sealed, and taped.
Make sure the power is on high speed for
heavy cooking.
NOTE: For all other inquiries, please contact Victory Range Hoods.