66251850 - V2.1 - 15/03/20
-2 -
4000 Series
Art.4384/4384X - Installation instructions
PROGRAMMING
The programming consists of the following settings:
Unit ID (1..15);
Door opening time (2 or 6 seconds);
Conversation time (1 or 2 minutes);
Addressing order of the buttons.
Main camera selection for Art.4384 versions or programming mode for Art.4384X versions.
The settings are carried out through the 8 way dip-switch (reference
L
on Fig. 2) accessible from the rear side of the module.
PROGRAMMING THE UNIT ID
Switch Nr.1 Nr.2 Nr.3 Nr.4 ID
ON
1 3 5 72 4 6 8
OFF OFF OFF OFF 1
ON
1 3 5 72 4 6 8
ON OFF OFF OFF 2
ON
1 3 5 72 4 6 8
OFF ON OFF OFF 3
ON
1 3 5 72 4 6 8
ON ON OFF OFF 4
ON
1 3 5 72 4 6 8
OFF OFF ON OFF 5
ON
1 3 5 72 4 6 8
ON OFF ON OFF 6
ON
1 3 5 72 4 6 8
OFF ON ON OFF 7
ON
1 3 5 72 4 6 8
ON ON ON OFF 8
ON
1 3 5 72 4 6 8
OFF OFF OFF ON 9
ON
1 3 5 72 4 6 8
ON OFF OFF ON 10
ON
1 3 5 72 4 6 8
OFF ON OFF ON 11
ON
1 3 5 72 4 6 8
ON OFF ON ON 12
ON
1 3 5 72 4 6 8
OFF OFF ON ON 13
ON
1 3 5 72 4 6 8
ON OFF ON ON 14
ON
1 3 5 72 4 6 8
ON ON ON ON 15
PROGRAMMING THE DOOR OPENING TIME
Switch Nr.5 Setting Up
ON
1 3 5 72 4 6 8
OFF = 2 seconds
ON
1 3 5 72 4 6 8
ON = 6 seconds
PROGRAMMING THE CONVERSATION TIME
Switch Nr.6 Setting Up
ON
1 3 5 72 4 6 8
OFF = 1 minute
ON
1 3 5 72 4 6 8
ON = 2 minutes
PROGRAMMING THE ADDRESSING ORDER OF THE BUTTONS
Switch Nr.7
Setting Up
Button matrix Internal buttons
ON
1 3 5 72 4 6 8
OFF = 1 - 40 = 1, 2
ON
1 3 5 72 4 6 8
ON = 41 - 80 = 41, 42
PROGRAMMING THE MAIN CAMERA SELECTION
ONLY ART.4384 VERSIONS
Switch Nr.8 Setting Up
ON
1 3 5 72 4 6 8
OFF = Main camera internal
ON
1 3 5 72 4 6 8
ON = Main camera external
PROGRAMMING MODES ONLY ART.4384X VERSIONS
Switch 8 sets the programming mode: "Standard" (switch in OFF
position) or "Advanced" (switch in ON position).
In "Standard" mode settings are made by switches from 1 to 7.
In "Advanced" mode all programming is made via the "VX2X00
Programmer" PC software connected to RS485 via an Art.481 in-
terface. Please note that in this case the programming made by
switches from 1 to 7 wil be ignored.
Switch Nr.8 Setting Up
ON
1 3 5 72 4 6 8
OFF "Standard" programming mode
ON
1 3 5 72 4 6 8
ON "Advanced" programming mode