CONNECTION TERMINALS SIGNALS
ART.4384 VERSIONS
VID2 Video signal input (coax centre core)
GNDV Video signal ground (coax screen and 0V to camera)
+V2
Output to supply the external camera
if necessary
Max 12Vdc
150mA
BUS
BUS Connection terminals
BUS
PTE “Push to exit” active low input
GND Ground
NO Door open relay normally open contact
Max 12-24
Vac/dc 2A
C Door open relay common contact
+C Electric lock capacitor discharge output
VAUX
35Vdc power supply input (if used, the module is
powered locally and not from the BUS)
NC
Door open relay normally closed
contact
Max 12-24
Vac/dc 2A
ART.4384X VERSIONS
VID2 Video signal input (coax centre core)
GNDV Video signal ground (coax screen and 0V to camera)
+V2
Output to supply the external camera
if necessary
Max 12Vdc
150mA
BUS
BUS Connection terminals
BUS
PTE “Push to exit” active low input
GND Ground
NO Door open relay normally open contact
Max 12-24
Vac/dc 2A
C Door open relay common contact
+C Electric lock capacitor discharge output
VAUX
35Vdc power supply input (if used, the module is
powered locally and not from the BUS)
NC
Door open relay normally closed
contact
Max 12-24
Vac/dc 2A
GND Ground
B
RS-485 serial interface
A
TECHNICAL SPECIFICATIONS
Call buttons: Up to 94
Working voltage: Supplied by the BUS line
Power consumption: Stand-by: 50 mA
Operating: 165 mA
Working Temperature: -10 +50 °C
MAXIMUM ILLUMINATION DISTANCE FROM CAMERA AT NIGHT
The illumination LED’s within the camera will
illuminate the visitor when they are within
50cm of the camera.
CLEANING OF THE PLATE
Use a clean and soft cloth. Use moderate warm water or non-ag-
gressive cleansers.
Do not use:
• abrasive liquids;
• chlorine-based liquids;
• metal cleaning products.