EasyManua.ls Logo

Videx 8KC/3012 User Manual

Videx 8KC/3012
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
66250870-EN - V2.1 - 30/11/16
1
Audiokit 8KC
Audiokit 8KC Series - Installation instructions
Art.8KC/3011-3012-3111-3102G
Audiokit with digital codelock
GENERAL DIRECTIONS FOR INSTALLATION
In order to achieve the best results from the schematics described it is necessary to install only original VIDEX equipment, strictly
keeping to the items indicated on each schematic and follow these General Directions for Installation:
The system must be installed according to national rules in force, in any case the running of cables of any intercom unit must be
carried out separately from the mains (see the next paragraph for connection to mains and power supply installation);
All multipair cables should be compliant to CW1308 specication (0.5mm twisted pair telephone cable);
Cables for speech line and service should have a max resistance of 10Ω;
Lock release wires should be doubled up (Lock release wires and power supply wires should have a max resistance of 3Ω);
The cables sizes above can be used for distances up to 50m. On distances above 50m the cable sizes should be increased to keep
the overall resistance of the cable below the RESISTANCES indicated above;
Double check the connections before power up; 3 Power up the system then check all functions.
CONNECTION TO MAINS AND POWER SUPPLY MOUNTING INSTRUCTIONS
The system must be installed according to national rules in force, in particular we recommend to:
Connect the system to the mains through an all-pole circuit breaker which shall have contact separation of at least 3mm in
each pole and shall disconnect all poles simultaneously;
The all-pole circuit breaker shall be placed for easy access and the switch shall remain readily operable.
POWER SUPPLY INSTALLATION
Remove the terminal side covers by unscrewing the retaining screws;
Fix the power supply to a DIN bar or directly to the wall using two expansion type screws;
Switch o the mains using the circuit breaker mentioned above and then make the connections as shown on the installation
diagrams;
Check the connections and secure the wires into the terminals;
Replace the terminal covers and x them using the relevant screws;
When all connections are made, restore the mains.
LOCK RELEASE BACK EMF PROTECTION
A varistor must be  tted across the terminals on AC lock release
(Fig.1A)
and a diode must be  tted across the terminals on a DC
lock release
(Fig.1B) to suppress back EMF voltages. Connect the components to the lock releases as shown in  gures.
VARISTOR (MOV)
12V AC
LOCK RELEASE
Fig.1A
DIODE
1N4002
12V DC
LOCK RELEASE
Fig.1B
ENG

Questions and Answers:

Videx 8KC/3012 Specifications

General IconGeneral
BrandVidex
Model8KC/3012
CategoryIntercom System
LanguageEnglish

Summary

General Installation Directions

Connection to Mains and Power Supply Mounting

System connection to mains via all-pole circuit breaker for safety and accessibility.

Power Supply Installation

Steps for mounting and connecting the power supply unit, ensuring safe mains connection.

Lock Release Back EMF Protection

Fitting varistors/diodes for back EMF protection on lock releases.

Wiring Guide and Troubleshooting

Wiring Guide Line

Cable type and size recommendations for intercom wiring.

Trouble Shooting Guide

Steps to diagnose and resolve common system malfunctions like no power, no speech, or lock issues.

8000 Series Door Station Installation

Installing a Flush Mounting Door Station

Step-by-step guide for flush mounting the door station module and components.

Installing a Surface Mounting Door Station

Instructions for mounting the surface box and door station at the specified height.

How to Remove the Card Name Holder

Procedure for safely removing and refitting the card name holder from the module.

Digital Codelock Module (Art. 8800/8800-3)

Description and Operation

Overview of the codelock module's features, basic usage, and code entry.

Initialization and Programming

Steps for initial setup, setting engineer's/access codes, and relay timings.

System Reset and Re-Programming

Procedures for returning to factory settings and re-programming the codelock.

Technical Details

Terminal layouts and technical specifications for codelock modules.

Related product manuals