INTERCOMMUNICATION MODE – SW3.1
This switch establishes the intercommunication mode: in OFF position (default) intercommunication is between units in the same
apartment (same addresses but different extension); in ON position the intercommunication is between units in different apart-
ments (different addresses).
On installations where there are more than one intercom/videophone in the same apartment and intercommunication between different
apartments is required, only one intercom/videophone may be set with this function (SW3.1=ON, SW3.2=OFF, SW3.3=OFF). The other inter-
com/videophones in the apartment must be set for local intercommunication with extension addresses “2-4” (slaves). From the inter-
com/videophone set for intercommunication with other apartments it will be not possible to intercommunicate within the apartment but slave
extensions 2-4 will be able to intercommunicate with each other.
EXTENSION NO – SW3.2..3
If the intercommunication between apartments is enabled (switch 1 of SW3 = ON) leave these two switches in default position (both to OFF). Otherwise,
if the intercommunication is between the same apartment (switch 1 of SW3 = OFF), set the extension addresses starting always from 1. During the ex-
ternal call, all video monitors in the same flat will ring but the video will be shown only from the videmononitor with extension address 1.
2 3 Extension No.
OFF OFF 1 (default, master)
ON OFF 2 (slave)
OFF ON 3 (slave)
ON ON 4 (slave)
4
3
ON
2
1
=OFF
=ON
ON
SW3.2..3
SLAVE MODE - SW3.4
This set up concerns the answering mode of the video monitor when there is more than one unit (max 4) in the same apartment.
OFF (default) = during a call, only the video monitor with extension 1 (master) will show the video. ON = the video monitor will be
switched on independently of the extension address: in this case the video monitor must be supplied locally using a power sup-
ply Art.2321 and connecting respectively BUS+ to terminal 14 and BUS- to terminal 11 of the pcb connection board provided
with the Art.5980 (the local power supply is required for each black & white slave videophone or starting from the third slave vid-
eophone when are used all colour videophones). If you set ON this switch for one slave videophone, you must set ON the same switch also for
the relevant master videophone.
VIDEOMONITOR CONNECTION BOARD ART.5980
SIGNAL ON CONNECTION TERMINALS
Terminal Signal Description
1 GND
Ground
2 BUS1
Bus input
3 S1 Terminal controlled by the S1 button, connects terminals 3 and 5 until is pressed
4 BUS2
Bus input
5 S1 Terminal controlled by the S1 button, connects terminals 3 and 5 until is pressed
6 LED
Auxiliary LED power supply input (12Vdc)
7 S2 Terminal controlled by the S2 button, connects terminals 7 and 17 until is pressed
8 GND
Ground
9 GND
Ground
10 LB
Local bell input (active low)
11 GND
Ground
12
13
14 +VAUX
Auxiliary power supply input (to be used when the switch 4 of SW3 is set to ON)
15
16
17 S2 Terminal controlled by the S2 button, connects terminals 7 and 17 until is pressed
18 AL
Alarm input (not implemented yet)
19
20
4
3
ON
2
1
=OFF
=ON
ON
SW3.4
4
3
ON
2
1
=OFF
=ON
ON
SW3.1