Operating Instructions
VITODENS
100-W
5784 570 - 02 05/2017
Vitodens 100-W
B1HA Series and B1KA Combi Boiler
Wall-Mounted, gas-fired condensing boilers
On demand domestic hot water with Combi boiler
Read and save these instructions
for future reference.
IMPORTANT
Please file in Service Binder
Heating input: 21 to 125 MBH
6.2 to 36.6 kW
WARNING
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
WARNING
Improper installation, adjustment, and/
or operation could cause carbon monoxide
poisoning resulting in injury or loss of life.
This product must be installed and serviced
by a professional service technician who is
experienced and qualified in hot water boiler
installation and gas combustion.
Do not store or use gasoline or other
ammable liquids in the vicinity of this
or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliances.
Do not touch any electrical switches,
do not use any phone in your building.
Immediately call your gas supplier
from a neighbor’s phone. Follow
the gas supplier’s instructions.
If you cannot reach your gas supplier,
call the re department.
Installation and service must be
performed by a quali ed installer,
service agency or the gas supplier.
H

Other manuals for Viessmann B1HA

Questions and Answers

  • D
    Danielle GreerSep 7, 2025
    What does Fault code 30 mean on a Viessmann B1HA?
    • S
      sarah55Sep 7, 2025
      If your Viessmann Boiler displays Fault code 30, this indicates a short circuit in the boiler water temperature sensor. You should check the boiler water temperature sensor.
  • K
    kenneth48Aug 25, 2025
    What to do if my Viessmann B1HA Boiler starts a self-diagnostic check when turned on?
    • A
      Angela Lawrence DVMAug 25, 2025
      When the Viessmann Boiler is initially turned on, it starts a self-diagnostic check. Wait until the temperature display stabilizes and the boiler displays the actual temperature.
  • A
    Alexis StuartAug 25, 2025
    What to do if my Viessmann Boiler shows fault F4?
    • W
      wmccoyAug 26, 2025
      If your Viessmann Boiler displays fault code F4, there are several potential solutions: * Check the ignition module connection. * Check the gas train (control voltage 230 V) and the gas supply pressure. * Check the ionisation current, the electrode adjustment, and the gas line for air-locks.
  • D
    david17Sep 16, 2025
    What to do if Viessmann B1HA burner shuts down below set temperature?
    • R
      Ryan MartinezSep 16, 2025
      If your Viessmann Boiler burner shuts down below the set boiler water temperature and restarts immediately, check the flue system for tightness to prevent flue gas recirculation. Also, inspect the condensate drain and verify the gas flow pressure.
  • J
    Joshua HamptonSep 23, 2025
    What to do if Viessmann B1HA displays fault F4?
    • L
      Lisa FaulknerSep 23, 2025
      If your Viessmann Boiler is showing fault F4, check the ionisation current, the electrode adjustment, the condensate drain, and the gas line for airlocks.
  • R
    richardmckeeSep 12, 2025
    What to do if the fan in my Viessmann B1HA starts no after approx. 51 s?
    • W
      wwoodsSep 12, 2025
      If the fan in your Viessmann Boiler does not start after approximately 51 seconds, check the following: 1. The fan itself. 2. The fan connecting cables. 3. Power at the fan. 4. Fan control.
  • F
    fmurphySep 2, 2025
    What to do if Viessmann B1HA shows fault F4 (Check gas train)?
    • L
      Leslie AlvarezSep 3, 2025
      If your Viessmann Boiler displays fault F4 related to the gas train, you should check the gas train, ensuring the control voltage is at 230V. Also, verify the gas supply pressure.
  • C
    Connie WallerSep 3, 2025
    What to do if Viessmann B1HA Boiler shows fault F4 (Measure ionisation current)?
    • M
      mcdonaldcarolSep 3, 2025
      If you're seeing fault F4 on your Viessmann Boiler related to measuring ionization current, you should measure the ionization current. Also, check the electrode adjustment and inspect the gas line for any airlocks.
  • C
    Caroline BakerSep 23, 2025
    What does fault code 38 mean on Viessmann B1HA Boiler?
    • N
      Natalie FrankSep 23, 2025
      If your Viessmann Boiler displays fault code 38, which indicates a lead break in the boiler water temperature sensor, check the boiler water temperature sensor.
  • L
    Lisa Woods MDAug 29, 2025
    What does fault code 10 mean on my Viessmann Boiler?
    • S
      shawnwrightAug 29, 2025
      If your Viessmann Boiler displays fault code 10, it indicates a short circuit in the outside temperature sensor. Check the outside temperature sensor and lead.

Viessmann B1HA Specifications

General IconGeneral
ModelB1HA
Fuel TypeNatural Gas
Efficiency95% AFUE
Heat Exchanger MaterialStainless Steel
MountingWall-mounted
Control SystemVitotronic control system
Boiler TypeWall-mounted condensing boiler