Operating Instructions
VITODENS
100-W
5784 570 - 02 05/2017
Vitodens 100-W
B1HA Series and B1KA Combi Boiler
Wall-Mounted, gas-fired condensing boilers
On demand domestic hot water with Combi boiler
Read and save these instructions
for future reference.
IMPORTANT
Please file in Service Binder
Heating input: 21 to 125 MBH
6.2 to 36.6 kW
WARNING
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
WARNING
Improper installation, adjustment, and/
or operation could cause carbon monoxide
poisoning resulting in injury or loss of life.
This product must be installed and serviced
by a professional service technician who is
experienced and qualified in hot water boiler
installation and gas combustion.
Do not store or use gasoline or other
ammable liquids in the vicinity of this
or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliances.
Do not touch any electrical switches,
do not use any phone in your building.
Immediately call your gas supplier
from a neighbor’s phone. Follow
the gas supplier’s instructions.
If you cannot reach your gas supplier,
call the re department.
Installation and service must be
performed by a quali ed installer,
service agency or the gas supplier.
H

Other manuals for Viessmann B1KA

Questions and Answers

  • J
    Justin StevensAug 30, 2025
    What does fault code 18 mean on my Viessmann B1KA?
    • L
      Leslie HardingAug 30, 2025
      If your Viessmann Boiler displays fault code 18, it indicates a lead break in the outside temperature sensor. Check the outside temperature sensor and lead.
  • B
    Benjamin ButlerAug 29, 2025
    What does fault code 38 mean on my Viessmann Boiler?
    • J
      Jeremy EdwardsAug 30, 2025
      If your Viessmann Boiler displays fault code 38, it indicates a lead break in the boiler water temperature sensor. Check the boiler water temperature sensor.
  • E
    Erin HenryAug 29, 2025
    What does fault code 10 mean on my Viessmann B1KA Boiler?
    • F
      Felicia FrazierAug 29, 2025
      If your Viessmann Boiler displays fault code 10, it indicates a short circuit in the outside temperature sensor. Check the outside temperature sensor and lead.
  • M
    Michelle SchmidtSep 12, 2025
    How to solve control unit issues with no increase set value in Viessmann Boiler?
    • L
      laurenobrienSep 12, 2025
      If the control unit of your Viessmann Boiler is not increasing the set value, increase the set value and ensure heat is being drawn off.
  • K
    Kevin CookSep 16, 2025
    What to do if Viessmann B1KA Boiler burner shuts down below set temperature?
    • W
      William HamiltonSep 16, 2025
      If your Viessmann Boiler burner shuts down below the set boiler water temperature and restarts immediately, check the flue system for tightness to prevent flue gas recirculation. Also, inspect the condensate drain and verify the gas flow pressure.
  • S
    Sarah JordanSep 23, 2025
    What does fault code 38 mean on Viessmann B1KA Boiler?
    • D
      Dominique SmithSep 23, 2025
      If your Viessmann Boiler displays fault code 38, which indicates a lead break in the boiler water temperature sensor, check the boiler water temperature sensor.
  • D
    Dr. David Becker MDAug 27, 2025
    How to fix fault F9 on a Viessmann B1KA Boiler?
    • M
      megan54Aug 27, 2025
      To address fault F9 on your Viessmann Boiler, check the fan, the fan connecting cables, the power at the fan, and the fan control.
  • J
    James RodriguezAug 27, 2025
    What does fault code 50 mean on my Viessmann Boiler?
    • S
      scottjeffreyAug 27, 2025
      If your Viessmann Boiler displays fault code 50, it indicates a short circuit in the cylinder temperature sensor. You should check the sensor.
  • R
    Rodney RiveraAug 26, 2025
    What to do if my Viessmann B1KA shows displayed fault code 52?
    • C
      Caleb NelsonAug 26, 2025
      If your Viessmann Boiler is showing fault code 52, check the connections and lead to the flow sensor. If necessary, replace the sensor.
  • J
    Joe FlemingAug 25, 2025
    What to do if my Viessmann B1KA shows fault F4?
    • P
      Patricia BryantAug 26, 2025
      If your Viessmann Boiler displays fault code F4, there are several potential solutions: * Check the ignition module connection. * Check the gas train (control voltage 230 V) and the gas supply pressure. * Check the ionisation current, the electrode adjustment, and the gas line for air-locks.