Operating Instructions
VITODENS
100-W
5784 570 - 02 05/2017
Vitodens 100-W
B1HA Series and B1KA Combi Boiler
Wall-Mounted, gas-fired condensing boilers
On demand domestic hot water with Combi boiler
Read and save these instructions
for future reference.
IMPORTANT
Please file in Service Binder
Heating input: 21 to 125 MBH
6.2 to 36.6 kW
WARNING
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
WARNING
Improper installation, adjustment, and/
or operation could cause carbon monoxide
poisoning resulting in injury or loss of life.
This product must be installed and serviced
by a professional service technician who is
experienced and qualified in hot water boiler
installation and gas combustion.
Do not store or use gasoline or other
ammable liquids in the vicinity of this
or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliances.
Do not touch any electrical switches,
do not use any phone in your building.
Immediately call your gas supplier
from a neighbor’s phone. Follow
the gas supplier’s instructions.
If you cannot reach your gas supplier,
call the re department.
Installation and service must be
performed by a quali ed installer,
service agency or the gas supplier.
H

Other manuals for Viessmann B1KA

Questions and Answers

  • O
    ologanSep 1, 2025
    What to do if Viessmann B1KA Boiler displays fault F2?
    • L
      Laura WilliamsSep 1, 2025
      If your Viessmann Boiler is showing fault code F2, indicating that the temperature limiter has responded, you should check the heating system fill level and the circulation pump. Make sure to vent the system. Inspect the temperature limiter and its connecting leads. Finally, press the "Reset" button.
  • R
    rangeljonSep 1, 2025
    What to do if Viessmann B1KA shows fault E3?
    • S
      Sandra AguilarSep 1, 2025
      If your Viessmann Boiler displays fault E3, indicating a fault in the safety chain, you should check the temperature limiter and its connecting leads. Also, check the control unit; replace it if necessary.
  • D
    Dustin OdomSep 2, 2025
    How to fix Viessmann B1KA fault F9?
    • N
      Nathaniel JuarezSep 2, 2025
      If your Viessmann Boiler displays fault F9, and the cause is fan speed being too low during burner start, examine the fan, its connecting cables, and the power supply. Check the fan control. Then, press the "Reset" button.
  • S
    Susan HarrisSep 2, 2025
    What to do if Viessmann B1KA shows fault F4 (Check gas train)?
    • B
      Bruce MillerSep 3, 2025
      If your Viessmann Boiler displays fault F4 related to the gas train, you should check the gas train, ensuring the control voltage is at 230V. Also, verify the gas supply pressure.
  • T
    Tamara KnightSep 3, 2025
    What to do if Viessmann B1KA Boiler shows fault F4 (Measure ionisation current)?
    • T
      Troy WilliamsSep 3, 2025
      If you're seeing fault F4 on your Viessmann Boiler related to measuring ionization current, you should measure the ionization current. Also, check the electrode adjustment and inspect the gas line for any airlocks.
  • B
    Bryan HarperSep 4, 2025
    What to do if Viessmann Boiler shows fault F9 after approx. 51 s?
    • C
      Chad SilvaSep 4, 2025
      If your Viessmann Boiler displays fault F9 after approximately 51 seconds, check the fan, fan connecting cables, power to the fan, and fan control.
  • T
    Tracy ShahSep 4, 2025
    How to solve the issue when Viessmann B1KA Boiler control unit issues no Increase set value?
    • B
      Bobby WilliamsSep 4, 2025
      To address the issue where the Viessmann Boiler control unit does not increase the set value, increase the set value and ensure that heat is being drawn off.
  • D
    Douglas Baker PhDSep 5, 2025
    What to do if Viessmann B1KA Boiler shows Fault F4 (Check the ionisation current)?
    • J
      Jimmy ScottSep 5, 2025
      If your Viessmann Boiler shows Fault F4 related to the ionization current, you should check the ionization current itself. Also, inspect the electrode adjustment and the gas pipe, ensuring there are no air-locks.
  • K
    Katherine JacksonSep 5, 2025
    What to do if Viessmann B1KA Boiler shows Fault F4 (Check the gas train)?
    • M
      Mrs. Cynthia JohnsonSep 5, 2025
      If your Viessmann Boiler displays a Fault F4 related to the gas train, examine the gas train, ensuring the control voltage is at 230 V. Also, verify the gas supply pressure.
  • K
    Keith PooleSep 6, 2025
    What to do if Viessmann B1KA Boiler stops below the set boiler water temperature and restarts immediately?
    • S
      Samantha TurnerSep 6, 2025
      If your Viessmann Boiler stops below the set boiler water temperature and restarts immediately, you should check the flue gas system for tightness, looking for flue gas recirculation. You should also check the gas flow pressure.

Viessmann B1KA Specifications

General IconGeneral
BrandViessmann
ModelB1KA
CategoryBoiler
LanguageEnglish