EasyManua.ls Logo

Viessmann B2HAH13 - Settings the Room Temperature; Setting the Heating Program for Central Heating

Viessmann B2HAH13
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
5461 885 - 04
Vitodens 200-W B2HA/B2HB, 222-F B2TA/B2TB Operating
Heating
Setting the Room Temperature
Setting the room temperature for standard heating mode
Factory setting: 68°F (20°C).
For the heating circuit displayed in the header
Proceed as described on page 11.
For the other heating circuits
Extended menu:
1.
2. “Heating”
3. Select the heating circuit if necessary (see page 16)
4. “Set room temperature”
5. Set the required value
Setting the room temperature for reduced heating mode
(night setback)
Factory setting: 65°F (18°C).
Extended menu:
1.
2. “Heating”
3. Select the heating circuit if necessary (see page 16)
4. “Set reduced room temp”
5. Set the required value
The rooms are heated to this temperature:
H Between the time phases for standard heating mode
(see page 18).
H In the holiday program (see page 21).
Factory setting: “Heating and DHW”
For the heating circuit displayed in the header
Proceed as described on page 11.
For the other heating circuits
Extended menu:
1.
2. “Heating”
3. Select the heating circuit if necessary (see page 16)
4. “Heating program”
5. “Heating and DHW”
H The rooms of the selected heating circuit are heated
in accordance with the room temperature and time
program settings.
H DHW is reheated in accordance with the set DHW
temperature and time program (see chapter “DHW
heating”).
Setting the Heating Program for Central Heating

Table of Contents