4
1. Information Disposal of packaging ............................................................................ 7
Symbols ................................................................................................. 7
Intended use .......................................................................................... 7
Product information ................................................................................ 8
Spare parts lists .................................................................................. 8
2. Installation sequence Installing the ventilation programming unit ............................................ 9
Electrical connections ............................................................................ 9
Vitovent 200-C: Connecting the connecting cable .............................. 10
Vitovent 300-C: Connecting the connecting cable .............................. 12
Vitovent 300-W: Connecting the connecting cable ............................. 12
Installing and removing the programming unit ....................................... 13
3. Commissioning, inspec-
tion, maintenance
Steps - commissioning, inspection and maintenance ............................ 14
4. Parameter settings Parameter level 1 in the service menu .................................................. 19
Activating the service menu (set parameters marked
!
) .................. 19
Deactivating the service menu ........................................................... 19
Setting parameters ................................................................................ 20
Bit field ................................................................................................ 20
Restoring the delivered condition (Reset) .............................................. 21
7D00 Enable Vitovent
!
....................................................................... 21
7D01 Enable electric preheating coil
!
................................................ 21
7D08 Set extract air temperature ........................................................... 22
7D0A Flow rate, reduced ventilation
!
................................................ 22
7D0B Flow rate nominal ventilation
!
.................................................. 22
7D0C Flow rate intensive ventilation
!
................................................ 22
7D0F Min. supply air temperature for bypass ........................................ 22
7D2C Strategy, passive frost protection
!
........................................... 23
7D2E Type of heat exchanger
!
.......................................................... 23
7D2F Installation position
!
................................................................. 24
7D3A Function, external 230 V input, ventilation
!
............................. 24
7D3B Duration, bathroom vent.
!
........................................................ 24
7D5E Starting block, ventilation periods part 1
!
................................ 24
7D5F Starting block, ventilation periods part 2
!
................................. 25
7D71 Control voltage matching, supply air fan
!
................................. 25
7D72 Control voltage matching, exhaust air fan
!
.............................. 25
7D76 Sensor matching, ODA temp downstream of preheat. coil
!
..... 26
7D77 Sensor matching, supply air temperature
!
............................... 26
7D79 Sensor matching, extract air temperature
!
............................... 26
7D83 Continuous operatn ON/OFF
!
.................................................. 26
7D84 Duration, economy mode
!
........................................................ 26
7D85 Duration, intensive mode ............................................................. 27
C101 Preheating coil
!
........................................................................ 27
C102 Reheater coil
!
........................................................................... 27
C105 Humidity sensor
!
...................................................................... 27
C106 CO2 sensor
!
............................................................................. 28
C108 Set extract air temperature ........................................................... 28
C109 Background vent.
!
.................................................................... 28
C10A Reduced ventilation
!
................................................................ 28
C10B Standard ventilation
!
................................................................ 29
C10C Intensive ventilation
!
................................................................ 29
C1A0 Bypass operation
!
.................................................................... 29
C1A1 Central heating and heat recovery
!
......................................... 29
C1A2 Imbalance permitted
!
............................................................... 29
C1A3 Specified imbalance
!
............................................................... 30
C1A4 Set reheating coil temperature
!
............................................... 30
C1A6 Sensitivity, humidity sensor
!
.................................................... 31
Index
Index
5816558