6.3 Connection of the DHW circulation pipe with cylinder banks
General information
■ Connect the DHW circulation pipe with detachable fittings.
■ Install the cylinder banks with DHW circulation according to the
diagrams below to ensure that each individual cylinder is heated
evenly.
In conjunction with boilers or district heating systems without a return
temperature limit on the heating water side and for operation on the
heating side with saturated steam up to 1 bar (0.1 MPa) pressure and
a DHW circulation pipe:
In conjunction with district heating systems with a return temperature
limit on the heating water side and/or several DHW circulation pipes:
Installing the Vitocell 100-V and Vitocell 300-V as a cylinder bank
Connection in conjunction with a district heating system without return temperature limit or in conjunction with boilers (low temperature opera-
tion) and a simple DHW circulation pipe
A
Draw-off points
B
DHW circulation pipe
C
DHW
D
DHW circulation pump
E
Check valve
F
Cold water
Installation — DHW cylinders
(cont.)
38
VIESMANN
DHW heating
6
5414646