EasyManua.ls Logo

Viessmann VITOTRONIC 200 - Page 10

Viessmann VITOTRONIC 200
108 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
Equipment and functions
The heat pump types differ in their equipment levels:
■
DHW cylinder
■
Electric booster heater (instantaneous heating water
heater)
■
High efficiency circulation pumps
■
…
The heat pump types differ in the available functions:
■
Number of heating circuits
■
Solar DHW heating
■
Central cooling
■
Noise reduction
■
Output control
■
Utilisation of power generated on site
■
Utilisation of excess power from the grid (Smart Grid)
■
…
Your contractor will have listed the equipment and
functions of your heating system in the form on
page 97.
Mechanical ventilation systems
Mechanical ventilation systems provide controlled ven-
tilation of detached houses or apartments.
If your Viessmann system includes mechanical ventila-
tion, the central ventilation unit can be controlled and
operated by the heat pump control unit.
Ventilation operation adapts automatically to your
requirements via a time program. "Economy mode"
and the "Holiday program" help you to save energy.
With "Intensive operation", you increase the air
changes in the building and quickly expel odours and
moisture to the outside.
The following central ventilation units are supported:
Vitovent 200-C
Vitovent 200-C is suitable for detached houses or
apartments with up to 120 m
2
of living space.
Vitovent 200-C meets the requirements for passive
house use.
The ventilation unit can either be mounted on a wall or
installed on the ceiling.
As well as being controlled by the heat pump control
unit, ventilation can also be activated by a switch or
button (bathroom switch) connected to the ventilation
unit, e.g. if you need the highest ventilation level for a
short period.
Vitovent 200-W
Vitovent 200-W is suitable for detached houses or
apartments with up to 230 m
2
of living space.
This ventilation unit is mounted on a wall.
To prevent moisture damage to the building, the venti-
lation unit adjusts the air changes automatically,
depending on the relative humidity in your rooms
(accessories required).
Vitovent 300-C
Vitovent 300-C is suitable for detached houses or
apartments with up to 90 m
2
of living space.
Vitovent 300-C meets the requirements for passive
house use.
The ventilation unit can either be mounted on a wall or
installed on the ceiling.
To ensure good air quality in your building, the ventila-
tion unit adjusts the air changes automatically, depend-
ing on the relative humidity and/or carbon dioxide con-
centration in your rooms (accessories required).
Vitovent 300-F
Vitovent 300-F is suitable for detached houses or
apartments with up to 180 m
2
of living space.
Vitovent 300-F meets the requirements for passive
house use.
This ventilation unit is installed near the heat pump
control unit.
To ensure good air quality in your building, the ventila-
tion unit adjusts the air changes automatically, depend-
ing on the relative humidity and/or carbon dioxide con-
centration in your rooms (accessories required).
In addition to actual mechanical ventilation, your rooms
can also be supplied with heat from the heat pump via
the ventilation system. This method of heating the sup-
ply air can be used as the sole heat source in buildings
with very good thermal insulation. For supply air heat-
ing, your contractor will have connected the ventilation
unit to heating circuit HC1 of your heat pump. This
means heating circuit HC1 is then a ventilation heating
circuit.
Vitovent 300-W
Vitovent 300-W is suitable for detached houses or
apartments with up to 370 m
2
of living space.
Introductory information
Appliance description (cont.)
5790940