Command Control via the Network
Reply Data format
The connection ID (the data is same as the connection ID data on the sending
data format) is attached to the RS-232C commands reply data.
<ACK reply>
Reply
Connection
ID
0x06 1 byte
<NAK reply>
Reply
Connection
ID
0x15 1 byte
<Error reply>
Reply Error code
Connection
ID
0x1C 2 bytes 1 byte
<Data reply>
<Projector busy reply>
<Authentication error reply>
Reply Data
Connection
ID
0x1D 2 bytes 1 byte
Reply Status code
Connection
ID
0x1F 2 bytes 1 byte
Reply
Authentication Er-
ror code
Connection
ID
0x1F 0x04 0x00 1 byte
91ViewSonic PJ1158