2726
Dimensions & Specifications
(VBCV Wall Custom Ventilator System 30”, 36”, 42”, 48”, 54”, 60” & 66”)
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
BBoottttoomm CCuuttoouutt DDiimmeennssiioonnss
*For best results,
center the unit over
the burners of the
cooking product
(front to back; right
to left).
Wall Hoods
Description A (Hood Width) B (Hood Depth)
30” W. 27-7/16” (69.7 cm) 21-7/16” (54.5 cm)
36” W. 33-7/16” (84.9 cm) 21-7/16” (54.5 cm)
42” W. 39-7/16” (100.2 cm) 21-7/16” (54.5 cm)
48” W. 45-7/16” (115.4 cm) 21-7/16” (54.5 cm)
54” W. 51-7/16” (130.7 cm) 21-7/16” (54.5 cm)
60” W. 57-7/16” (145.9 cm) 21-7/16” (54.5 cm)
66” W. 63-7/16” (161.1 cm) 21-7/16” (54.5 cm)
MMaakkee ssuurree tthhee bbaacckk wwaallll
ooff tthhee ccuussttoomm hhoooodd
ccaannooppyy iiss fflluusshh wwiitthh tthhee
ccuuttoouutt ssoo tthhee vveennttiillaattoorr
ssyysstteemm mmaayy bbee mmoouunntteedd
aass sshhoowwnn oonn ppaaggee 2255..
Installing Hood Canopy
CCuussttoomm HHoooodd
CCaannooppyy
1) Position ventilator
system inside of the
custom hood canopy
and center it front to
back and left to right.
2) Bottom mounting holes
fasten ventilator system
to bottom of custom
hood canopy with the
screws provided.
BBuuiilltt--IInn VVeennttiillaattoorr
SSyysstteemm
3) OPTIONAL
Rear mounting holes fasten
ventilator system to rear of
custom hood canopy.
(Custom Hood Canopy Cutouts)
VBCV Wall Custom Ventilator System
Description 30” 36” 42” 48” 54” 60” 66”
Number of lights
2 2 2 3 3 4 4
Number of filters
2 2 2 3 3 4 4
Heat lamps
1 1 1 2 2 2 2
Interior ventilator kits
VINV300/
600/1200*
VINV300/
600/1200*
VINV600/
1200*
VINV1200* VINV1200* VINV1200* VINV1200*
Exterior ventilator kits
DEV900/
1200*
DEV900/
1200*
DEV900/
1200*
DEV1200*/
1500**
DEV1200*/
1500**
DEV1200*/
1500**
DEV1200*/
1500**
In-line ventilator kits
DIL900/1200 DIL900/1200 DIL900/1200 DIL1200 DIL1200 DIL1200 DIL1200
Interior duct size
7”/10”
(17.8/25.4 cm)
7”/10”
(17.8/25.4 cm)
7”/10”
(17.8/25.4 cm)
10”
(25.4 cm)
10”
(25.4 cm)
10”
(25.4 cm)
10”
(25.4 cm)
Exterior duct size
10” (25.4 cm)
Interior—Maximum amps
5.9/9.0 5.9/9.0 5.9/9.0 11.5 11.5 11.9 11.9
Exterior—Maximum amps
8.7/6.0 8.7/6.0 8.7/6.0 8.5/9.2 8.5/9.2 8.9/9.2 8.9/9.2
In-Line—Maximum amps