38
CAUTION: If not using a duct cover, using screws
provided, make sure top mounting screws are secured
into soffit or cabinet framing. Use additional mounting
screws, if necessary.
Connect black to black, white to white, and the
green/bare wire under the green screw.
NOTE: Housing wiring must be properly installed for
wiring to be correct when wiring unit.
BLACK
BLACK
WHITE
W
HITE
GREEN
BARE OR GREEN
39
Replace electrical box cover. Make connection to
breaker box.
Slide spacer front over front lip. Push spacer rear up,
then slide back over rear lip.
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
Remove damper and discard with transition.
Turn recirculating unit upside down. Place vent hood
upside down on recirculating unit.
Installation (VWH 10”H. Wall Hoods w/Recirculating Kit)
Measure distance from ceiling to canopy.
Slide the duct cover in place and fasten from inside
canopy using the sheet metal screws provided.
Duct Cover Option (VWH 10”H. Wall Hoods w/Standard Ventilator)
Slide filter front over front lip. Push filter rear up, then
slide back over rear lip.
CAUTION: Secure vent hood to wall using screws
provided. Use additional mounting screws and wall
anchors, if necessary.