22
Diagnostics
Service Tests (continued)
202 Default Defrost Operation
Press the refrigerator temperature “UP” or “DOWN” keypad to toggle defrost operation from normal
adaptive defrost (OFF position) to minimum time between defrosts (ON position).
211 Fresh Food Temperature Offsets
Press the refrigerator temperature “UP” or “DOWN” keypad to toggle calibration of fresh food temperature
plus or minus in 1°F increments up to 6°F.
Note: Temperature will read in fahrenheit regardless of what current temperature scale is being used.
212 Freezer Temperature Offsets
Press the refrigerator temperature “UP” or “DOWN” keypad to toggle calibration of freezer temperature plus
or minus 1°F in increments up to 6°F.
Note: Temperature will read in fahrenheit regardless of what current temperature scale is being used.
221 Reset Default Settings (CAUTION: this will reset all adjustments made prior to this test)
Press the refrigerator temperature “UP” keypad to toggle reset to factory default settings dEF.
202 OFF
Press either button to toggle
through test cycles
Press either button to cycle normal
adaptive defrost (OFF) to minimum
time between defrosts (ON)
211 1
Press either button to toggle
through test cycles
Press either button to change
calibration of fresh food temperature
plus or minus in 1˚ increments
212 1
Press either button to toggle
through test cycles
Press either button to change
calibration of freezer temperatur
e
221
Press either button to toggle
through test cycles
Press either button to reset
to factory default (dEF)