33
RS02
Premendo
1 volta UP
Premendo
2 volte UP
Premendo
3 volte UP
Starting with the gate/barrier not fully closed, after entering programming mode by pressing the UP, OK, and AP/CH button once, the gate/barrier starts
closing to nd the mechanical stop for closing. It automatically starts opening at low speed until it reaches the mechanical stop for opening. After 2 seconds
the gate/barrier starts closing at cycle speed and slows down approximately 50 cm from the mechanical catch and continues until completely closed. The
control panel saves the gate/barrier travel and automatically performs a complete opening and closing cycle to save the current thresholds with default
deceleration speed and distances. The word END on the display indicates the end of calibration.
8.2 RAD: remote control management menu is divided into 4 parameters:
Pressing
1 time up
Pressing
2 times up
Pressing
3 times up
EN