10
SW24.W
EN
TRV
T15
Stop approach force reduction distance motor 1
Indicates the distance from the mechanical stop starting from which the motor 1 force is
reduced by half (used to adjust the impact of the leaf on the mechanical stop).
This happens only when the control panel works with encoder and proximity limit switch or
without limit switch.
Default
OFF
OFF Force reduction o
10 Minimum force reduction distance
100 Maximum force reduction distance
T16
Stop approach force reduction distance motor 2
Indicates the distance from the mechanical stop starting from which the motor 2 force is
reduced by half (used to adjust the impact of the leaf on the mechanical stop).
This happens only when the control panel works with encoder and proximity limit switch or
without limit switch.
Default
OFF
OFF Force reduction o
10 Minimum force reduction distance
100 Maximum force reduction distance
T17
Easy release
Disengagement time after manoeuvre to reduce the motor pressure on the mechanical stop
(adjustable at intervals of 100 ms)
Caution:
Leave this parameter in OFF when there is an electrical lock.
Default
OFF
OFF No disengagement
10 100 ms (minimum disengaging)
50 500 ms (maximum disengaging)
T18
Oset time in opening
Default
3
0 No oset
60 60 s
T19
Oset time in closing
Default
6
0 No oset
60 60 s
T24
Normal speed when opening motor 1
Default
90
1 minimum speed
100 maximum speed
T25
Normal speed when opening motor 2
Default
90
1 minimum speed
100 maximum speed
T26
Normal speed when closing motor 1
Default
90
1 minimum speed
100 maximum speed
T27
Normal speed when closing motor 2
Default
90
1 minimum speed
100 maximum speed
T28
Slowdown speed when opening motor 1
Default
30
1 minimum speed
100 maximum speed
T29
Slowdown speed when opening motor 2
Default
30
1 minimum speed
100 maximum speed