7
SW24.W
EN
MOT
Motor parameters
O1
Type of gear motor used
Default
OFF
Warning!
The motor type parameter is set to OFF by default. When set to OFF, the
control unit does not execute any command! It is necessary to set the motor
type parameter according to the type of gearmotor with which the control
unit is used.
OFF The motor type parameter is set to OFF by default. When set to OFF, the control unit does
not execute any command! It is necessary to set the motor type parameter according to
the type of gearmotor with which the control unit is used.
1 Ekko 300D (EAM2) or Ekko 400D (EAM3)
2 Hiddy 200D (EIM1)
3 Hiddy 350D (EIM2.24)
O2
Type of position control
Automatically set with the choice of gear motor. You are advised not to change the set-
ting given by the type of gear motor.
Default
3
2 Virtual encoder: the control panel calculates the gate position using the electric motor
operating parameters
3 Encoder for Ekko 300D (EAM2), Ekko 400D (EAM3), Hiddy 200D (EIM1)
O3
Type of limit switch on opening
Automatically set with the choice of gear motor. You are advised not to change the set-
ting given by the type of gear motor.
Default
OFF
OFF No limit switch on opening: the electric motor stops at the end of the working time
1 Stop limit switch on opening: the limit switch stops the motor
2 Limit switch in proximity opening: the limit switch allows the manoeuvre to continue at the
approach speed set until it detects the mechanical stop
O4
Type of limit switch on closing
Automatically set with the choice of gear motor. You are advised not to change the set-
ting given by the type of gear motor.
Default
OFF
OFF No limit switch on closing: the electric motor stops at the end of the working time
1 Stop limit switch on closing: the limit switch stops the motor
2 Limit switch in proximity closing: the limit switch allows the manoeuvre to continue at the
approach speed set until it detects the mechanical stop
LRNT
Gate travel calibration
LRNE
Rapid travel calibration.
The calibration is done fully automatically and sets:
- The slowdown in opening and closing at 20% of the total travel
- O󰀨set in opening at 3 s and in closing at 6 s
- Pedestrian opening at 30% of the total travel for the rst leaf
Pressing
button
Msg on
display
Phase description
- PP Wait for start of calibration procedure
PP CL 2 When button pressed: motor 2 closing and search for closing stop
- CL 1 Motor 1 closing and search for closing stop
- OP 1 Motor 1 opening travel measurement and search for stop
OP 2 Motor 2 opening travel measurement and search for stop
- CL 2 Motor 2 closing travel measurement
CL 1 Motor 1 closing travel measurement
- OPC1 Motor 1 opening current curve reading
- OPC2 Motor 2 opening current curve reading
- CLC2 Motor 2 closing current curve reading
- CLC1 Motor 1 closing current curve reading
- END End of procedure