EasyManua.ls Logo

Vimar ELVOX SW24.W - Page 10

Vimar ELVOX SW24.W
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
SW24.W
EN
LRNT LRNA
Advanced travel calibration.
The calibration allows the installer to choose:
- Slowdown position in opening and closing
- O󰀨set for opening and closing
- Pedestrian opening position
Pressing
button
Msg on
display
Phase description
- PP Wait for start of calibration procedure
PP CL 2 When button pressed: motor 2 starts closing and searches for closing
stop
- CL 1 Motor 1 starts closing and searches for closing stop
PP OP 1 Start opening motor 1
When button pressed: slowdown start position on opening setting.
PP OP 1 Continuation of motor 1 opening at slowing speed.
When button pressed: end of travel position setting.
No button pressed: continuation to the stop.
PP OP 2 Start opening motor 2
When button pressed: slowdown start position on opening setting.
PP OP 2 Continuation of motor 2 opening at slowing speed.
When button pressed: end of travel position setting.
No button pressed: continuation to the stop.
PP CL 2 Start closing motor 2
When button pressed: slowdown start position on closing setting.
- CL 2 Continuation of motor 2 closing at slowdown speed up to stop.
PP CL 1 Start closing motor 1
When button pressed: slowdown start position on closing setting.
- CL 1 Continuation of motor 1 closing at slowdown speed up to stop.
OPED Start pedestrian opening.
When button pressed: pedestrian opening position setting
- CPED Leaf closing from pedestrian opening position
PP DLOP Start opening.
When the o󰀨set time setting in opening button is pressed, motor 2
starts.
PP DLCL Start closing.
When the o󰀨set time setting in closing button is pressed, motor 1 starts.
- END End of procedure
Self-calibration
If the gate travel parameter is changed, there is no need for the installer to run new calibrations, however, when chang-
ing the travel parameters, the control panel needs to learn the current curve again, thus disabling the obstacle detection
only during the self-calibration manoeuvre.
Self-calibration is appropriately signalled:
- on the control panel display by the code AT
- by the light ashing at twice the normal frequency
The events generating self-calibration are:
- change in parameters: T24, T25 ,T26, T27, T28, T29, T30, T31, T32, T33, T34, T35, T40, T41.
- loading of settings from a MEM.W memory card
- reset/import of settings from the By-gate Pro