9
a
a
a
7511001
FIG.6
FIG.7
7.8) Use
While the platform lift is in motion the
wheel¬chairs brakes must be engaged and if it is
electric it must be switched off.
Floor controls:
The controls must be kept pressed throughout the
transit and cut out the lift if released. The oor locks
and the on-board control panel are only operational if
the key has been inserted.
- Insert the key (Fig. 6/a) on the control panel at the
oor and turn it to “1”.
WARNING: Even if the unit is used by more than
one person, only one key must be used.
- Press the call button (Fig. 5/b) and wait for the lock
to open.
If the platform is not at the oor, call it, keep the call
button depressed until the platform reaches the oor,
where it will stop and the gates will open automatically.
If the platform is at the oor, press the but¬ton and the
gates will unlock automatically, granting access to the
platform. The gates are tted with a sprung closing
system.
On-board controls:
- Insert and turn the key on the on-board control panel.
- Select the oor required.
The up/down button must be held down until the
des¬tination oor is reached. The travel direction can
be changed at any moment. If the button is released,
the platform stops immediately. Once the destination
oor is reached, the platform stops and the gates unlock
automatically.
- Turn the key to 0 (off) and remove it.
- Red emergency stop button.
This button, provided on the control panel on the lift
only, stops the lift immediately regardless of its travel
direction.
To restore the lift to operating mode, turn the stop button
clockwise through 45°.
- Alarm
The alarm buzzer is activated by pressing the ALARM
button on the platform control board.
7.9) Operating Precautions
- The platform must be started and stopped following
the instructions provided in this manual.
- Keep the special keys for opening the gate locks and
main electrical panel in emergencies out of reach of
children or unauthorised persons.
- Always keep the documentation supplied with the unit
(manual, electrical diagrams, warranty) in a safe place.