73
Turbine Station Conguration Guide
A100K11194
11 Restoring Factory Defaults
A Turbine IP Station may have to be reset to its original factory default settings if, for instance, the
password to the station web interface is forgotten. The defaults can either be set to Activated DHCP
or Static IP.
11.1 Reset to Factory Default Settings with Activated DHCP
To reset:
1. While pressing any button, power up the station by connecting to a
PoE switch.
2. Hold the button until the station audio starts counting, and release
the button on count 1.
3. Press and hold the button on count 5 and release on count 0.
- if there is no 0 count, the procedure has failed and you have to start again
4. Press the call key, number keys or DAKs to make the station
speak its IP address.
Factory default values
Station IP address: (determined by DHCP server)
Username: admin
Password: alphaadmin
11.2 Reset to Factory Default Settings with Static IP
To reset:
1. While pressing any button, power up the station by connecting to a
PoE switch.
2. Hold the button until the station audio starts counting, and release the
button on count 1.
3. Press and hold the button on count 3 and release on count 0.
- if there is no 0 count, the procedure has failed and you have to start again
4. Press the call key, number keys or DAKs to make the station speak its
IP address.
Factory default values
Station IP address: 169.254.1.100
Username: admin
Password: alphaadmin