23
© 2015 Directed. All rights reserved.
1. Aux/Trunk Icon Type: sets the name to be displayed in the Text Field when the Aux/Trunk output is
activated/de-activated.
2. AUX 1 Timed Output: sets the output duration in 1 second intervals up to 90 seconds for AUX 1.
3. AUX 1 Icon Type: sets the name to be displayed in the Text Field when the AUX 1 output is activated/
de-activated.
4. AUX 2 Timed Output: sets the AUX 2 “Timed” output in 1 second intervals up to 90 seconds.
5. AUX 2 Icon Type: sets the name to be displayed in the Text Field when the AUX 2 output is activated/
de-activated.
6. AUX 3 Timed Output: sets the AUX 3 “Timed” output in 1 second intervals up to 90 seconds.
7. AUX 3 Icon Type: sets the name to be displayed in the Text Field when the AUX 3 output is activated/
de-activated.
8. AUX 4 Timed Output: sets the AUX 4 “Timed” output in 1 second intervals up to 90 seconds.
9. Remote Start Runtime: sets the duration of runtime when the engine is started by remote command.
10. Timer Mode Runtime: sets the duration of runtime when the engine is started by the Timer Mode and
Smart Start features.
11. Timer Mode Starts: sets the number of times the engine will be started by the Timer Mode and Smart
Start features.
12. Timer mode Intervals: sets the number of hours between engine starts by the Timer Mode and Smart
Start features.
13. Smart Start Low Temperature: sets the low temperature threshold required for Smart Start to start the
engine.
14. Smart Start High Temperature: sets the high temperature threshold required for Smart Start to start the
engine.
15. Smart Start Low battery (Volts): sets the low battery level threshold required for Smart Start to start the
engine.
16. Diesel Start Delay Timer: sets the delay before engine crank in 1 second intervals up to 90 seconds for
diesel engine vehicles.
17. Starter Release Fine Tune: adds or subtracts crank time in Tachometer mode in order to overcome
engine types that short crank or over-crank on the first start attempt.
18. Virtual Tach Fine Tune: adds or subtracts crank time in Virtual Tach mode in order to overcome engine
types that short crank or over-crank on the first start attempt.
19. Transmitter Programming: locks and unlocks the user’s ability to enter the remote control/Reset Menu
and manually change any functions using the Control Center.
20. Feature Programming: locks and unlocks the user’s ability to enter the Feature Menus and manually
change the main unit programming using the Control Center.