105 / 120INST-007080 / E eco-CONTROL EC200 2.0
TECHNICAL SPECIFICATIONS
11.1.5
Logical links of the outputs
Dosing (X1.12)
The output has H-level during the dosing process, otherwise it has L-level.
Program change active (X1.2)
When switching to a different program, the output has an H-level, otherwise an L-level.
Level alarm (X1.14)
The output is activated following successful initialisation (H-level). It switches to L-level if the
connected level sensor switches to L-level. “Settings/Sensors” can be used to activate or
deactivate level monitoring for “Level A” or “Level B”.
Status ready (X1.13)
When the control system has been switched on, initialisation is run. The output is activated
when the initialisation has been successfully completed (H-level).
Error message active (X1.3)
The output is activated following successful initialisation (H-level). If the control system
detects an error (see page 95, Error message), the output switches to L-level.
Warning blank shot (X1.4)
Only for 2-component dispensers: During an blank shot this output has H-level,
otherwise L-level. If a lead time (page 31) is specified for the blank shot,
this output goes to H-level accordingly earlier