SAFETY
2.4 Informal safety precautions
The following documents must be read, understood and followed. They must always be
available at the machine's operating location, and must be kept in legible condition:
The operation manual for this product
Generally applicable and local accident prevention and environmental protection
regulations
Safety data sheets for the conveyed materials, as well as for any cleaning products or
lubricants being used
2.5 Preventing damage to equipment
In order to prevent damage to equipment and to ensure precision dosing, ensure that
the connecting cable for a dispenser may only be connected or disconnected when
the power supply is switched off. Otherwise, the electronics in the drive motor could
be damaged
only original dosing pressure sensors adapted for the dosing control unit are to be used
the dispenser must never be operated without material (the stator will be destroyed)
the material inlet (feed) and the material outlet must never be closed during operation
the material outlet (e.g. dosing needle or mixer) must not be damaged or blocked
the dispenser is regularly checked and cleaned
the specifications in the product data sheet for the material are observed and adhered to

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ViscoTec preeflow eco-CONTROL EC200 2.0 and is the answer not in the manual?

ViscoTec preeflow eco-CONTROL EC200 2.0 Specifications

General IconGeneral
BrandViscoTec
Modelpreeflow eco-CONTROL EC200 2.0
CategoryControl Unit
LanguageEnglish

Related product manuals