Defines the purpose and basic working principle of the VivaChek™™ Fad Sync Blood Glucose Monitoring System.
Provides a visual and descriptive overview of the VivaChek™™ Fad Sync Blood Glucose Meter and test strips.
Details the symbols and icons displayed on the meter, explaining their meaning for user understanding.
Outlines general guidelines, precautions, and best practices for using the blood glucose monitoring system.
Highlights critical safety instructions, including single-patient use and handling precautions to prevent disease transmission.
Lists the limitations of the system's use and emphasizes the biohazardous nature of kit components.
Guides users through the process of setting the correct time and date on the glucose meter for accurate record-keeping.
Instructs users on how to adjust the meter's time and configure audio alerts for user preference.
Details the steps for pairing the meter with an iPhone and syncing data wirelessly using the VivaGuard™™ app.
Describes how to use the blood glucose meter without connecting to a smartphone or app.
Provides step-by-step instructions on how to correctly prepare and insert a test strip into the meter.
Guides users on how to assemble and adjust the lancing device for blood sample collection.
Explains how to lance the finger, obtain blood, and apply it to the test strip for measurement.
Covers the meter's countdown, result storage, and proper disposal of used test strips.
Details the procedure and considerations for collecting blood samples from sites other than the fingertip.
Provides expected blood glucose values for individuals without diabetes, categorized by time of day.
Offers steps to troubleshoot and resolve questionable or inconsistent blood glucose test results.
Explains the purpose, procedure, and interpretation of control tests to verify meter and strip performance.
Explains how the meter stores results and how to access and review stored blood glucose test data.
Provides instructions on how to recharge the meter's battery using various connection options and safety cautions.
Offers advice on system care and details the weekly cleaning and disinfection procedures for the meter.
Explains common error codes (E1-E9, HI, LO) displayed by the meter and provides recommended solutions for each.
Lists common symptoms associated with hypoglycemia (low blood glucose) and hyperglycemia (high blood glucose).
Details the technical features, operational parameters, and accuracy performance of the VivaChek™™ Fad Sync Blood Glucose Monitoring System.
Outlines the warranty terms and conditions for the VivaChek™™ Fad Sync Blood Glucose Monitoring System.
| Product Type | Blood Glucose Meter |
|---|---|
| Connectivity | Bluetooth |
| Display | LCD |
| Test Time | 5 seconds |
| Sample Type | Capillary whole blood |
| Operating Humidity | 10-90% RH |
| Sample Size | 0.5 µL |
| Measurement Range | 20-600 mg/dL |