VIVOTEK
156 - User's Manual
of window
position.
i<0~(m-1)>_win_i<0~2>_top 0 ~ 240 0 4/4 Top coordinate
of window
position.
i<0~(m-1)>_win_i<0~2>_width 0 ~ 320 0 4/4 Width of motion
detection
window.
i<0~(m-1)>_win_i<0~2>_height 0 ~ 240 0 4/4 Height of motion
detection
window.
i<0~(m-1)>_win_i<0~2>_objsize 0 ~ 100 0 4/4 Percent of
motion
detection
window.
i<0~(m-1)>_win_i<0~2>_sensitivity 0 ~ 100 0 4/4 Sensitivity of
motion
detection
window.
7.17 Tempering detection settings
Group: tampering_c<0~(n-1)> for n channel product (capability.tampering > 0)
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
enable <boolean> 0 4/4 Enable or disable tamper detection.
threshold 0 ~ 255 32 4/4 Threshold of tamper detection.
duration 10 ~ 600 10 4/4 If tampering value exceeds the ‘threshold’ for
more than ‘duration’ second(s), then tamper
detection is triggered.