EasyManua.ls Logo

Vivotek FE8171V - Page 130

Vivotek FE8171V
203 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VIVOTEK
130 - User's Manual
daynight
<product dependent>
day, night <product
dependent>
7/7 Current status of day,
night.
onlinenum_rtsp integer 0 6/7 Current number of RTSP
connections.
onlinenum_httppush integer 0 6/7 Current number of HTTP
push server
connections.
eth_i0 <string> <product
dependent>
1/7 Get network information
from mii-tool.
vi_i<0~(nvi-1)>
<product dependent>
<boolean> 0 1/7 Virtual input
0 => Inactive
1 => Active
(capability.nvi > 0)
7.3 digital input behavior define
Group: di_i<0~(ndi-1)> (capability.ndi > 0)
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
normalstate high,
low
high 1/1 Indicates open circuit or
closed circuit (inactive
status)
7.4 digital output behavior define
Group: do_i<0~(ndo-1)> (capability.ndo > 0)
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
normalstate open,
grounded
open 1/1 Indicate open circuit or
closed circuit (inactive
status)
7.5 security
Group: security
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
privilege_do
<product dependent>
view, operator,
admin
operator 6/6 Indicate which privileges
and above can control
digital output

Table of Contents

Other manuals for Vivotek FE8171V

Related product manuals