EasyManua.ls Logo

Vivotek FE8174 - Eptz Setting

Vivotek FE8174
226 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VIVOTEK
192 - User's Manual
unit string[32] Vivotek Inc. 6/6 Organizational unit name in the
certificate information.
commonname string[64] www.vivotek.
com
6/6 Common name in the certificate
information.
validdays 0 ~ 3650 3650 6/6 Valid period for the certification.
7.35 Storage management setting
Currently it’s for local storage (SD, CF card)
Group: disk_i<0~(n-1)> n is the total number of storage devices. (capability.storage.dbenabled > 0)
PARAMETER VALUE Default SECURITY
(get/set)
DESCRIPTION
cyclic_enabled <boolean> 0 6/6 Enable cyclic storage method.
autocleanup_enabled <boolean> 0 6/6 Enable automatic clean up method.
Expired and not locked media files will
be deleted.
autocleanup_maxage <positive
integer>
7 6/6 To specify the expired days for
automatic clean up.
7.36 ePTZ setting
Group: eptz_c<0~(n-1)> for n channel product. (capability.eptz > 0)
PARAMETER VALUE Default SECURITY
(get/set)
DESCRIPTION
tiltspeed -5 ~ 5 0 1/4 Tilt speed
panspeed -5 ~ 5 0 1/4 Pan speed
zoomspeed -5 ~ 5 0 1/4 Zoom speed
panoramicspeed 1 ~ 5 1 1/4 Panoramic speed
rotatespeed 1 ~ 5 1 1/4 Rotate speed
Group: eptz_c<0~(n-1)>_s<0~(m-1)> for n channel product and m is the number of streams which support
ePTZ. (capability.eptz > 0)
PARAMETER VALUE Default SECURITY
(get/set)
DESCRIPTION
patrolseq string[120] <blank> 1/4 The patrol sequence of ePTZ. All the
patrol position indexes will be
separated by ","